WISE-5800

Features

  • 80MHz CPU
  • Ethernet Interface
  • MicroSD Card (32GB max.)
  • I/O Expansion Board
  • Modbus RTU/TCP support
  • IF-THEN-ELSE Rule Engine
  • SMS Command Receiving and Notification
  • Connect with SCADA/HMI Systems

Description

WISE I/O module is an Intelligent I/O module designed by ICP DAS that functions as control units for remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive HMI interface that allows you to implement control logic on controllers with just a few clicks, no programming is required. With this powerful and easy-to-use interface, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development.

WISE Features

  • IF-THEN-ELSE logic rules execution ability
    WISE equips with an IF-THEN-ELSE logic Rule Engine, it offers IF-THEN-ELSE rule editing for you to set up the logic content. After completing rule editing and downloading to the WISE, the Rule Engine will loop execute the rules in order under specific conditions.
  • No programming is required to implement logic content on controllers
    WISE provides user-friendly Web UI pages for editing control logic on the controllers. With just a few clicks of the mouse you can set up and deploy logic rules without writing a single line of code.
  • No extra software tool is required; all operations can be done through the Web browsers
    The web-based HMI interface runs on regular Web browsers. To edit control logic, it only requires a browser to connect to the Web server on WISE controller. No extra software tool installation is needed.
  • Support various hardware modules that offer various I/O types
    The WISE-580x allows to connect with the XW-Board, I-7000 modules, and Modbus RTU/TCP Slave devices to allow users to design the best solution to meet their requirements.
  • Provide Timer and Schedule operation
    WISE-580x features two kinds of timing functions: Timer and Schedule. It allows you to perform specific tasks such as time delay, or schedule specific date or time for control logic execution. To ensure the accuracy of the WISE clock, it also has the ability to sync to an SNTP time server for time synchronization through the network.
  • Provide non-SSL Email message and CGI command sending functions
    WISE supports non-SSL Email message and CGI command sending functions. Email and CGI command functions are important function for real-time message communication. The sending action can be added to the logic edition as part of logic control to provide real-time message transmission or sending CGI command for device control in response to specific events.
  • Recipe function for Group Action operation
    WISE provides Recipe function that allows to execute a sequence of actions previously saved in the Recipe to response to IF-THEN-ELSE logic rules Conditions. You can create different Recipe sets to meet various requirements for different applications.
  • Real-time monitoring system status of I/O modules
    WISE supports Modbus TCP Protocol for users to perform real-time monitoring and control of the WISE I/O modules. WISE also provides an easy-to-view HMI web interface for real-time monitoring. It allows users to get important real time system information even without SCADA software. WISE-580x also features Modbus RTU Slave function.
  • Password protection for access control
    WISE HMI web page offers password protection. After loading in the webpage, you will be required to input the password before editing logic rules.
  • Data Logger function
    With a microSD card installed, WISE provides Data Logger function to real-time record the I/O data of the controller and sends the data files by FTP or Email to the control center for further administration management or data analysis.
  • Active I/O Sending function
    In addition to the Modbus TCP/RTU Slave function that enables SCADA software (or HMI device) to poll the I/O channels value of the WISE I/O module, now WISE-580x provide the new function “Active I/O Sending” for users. Based on the “Active I/O Sending” function, WISE-580x can send the I/O channels value of the controller actively to SCADA software (or HMI device) by event trigger (I/O channel value changed) or periodic cycle. This function will improve the efficiency of the data communication between WISE-580x and SCADA software (or HMI device).
    Please note: The SCADA software (or HMI device) must equip the Modbus TCP Slave function to receive the I/O channels data sent by WISE-580x.
  • Provides SMS command receiving function and alarm notification function (Only applies to WISE-5801(-MTCP))
    WISE equips SMS command receiving and alarm message notification function. It allows to include SMS alarm sending action into logic rules to send a pre-set SMS message to related personnel when an event occurs. In addition, WISE allows to receive the SMS commands sent by specific phones numbers to perform tasks such as real-time channel monitoring, channel data modification and logic rules execution (triggered by SMS).
WISE-5800

Intelligent I/O Controller with Modbus/RTU Support

  • Built-in IF-THEN-ELSE rule engine for logic operation
  • No more programming. Click and get done!
  • Support I/O, Counter, Timer, Email, Recipe operations
  • Data logger and data files send back function supported
  • Modbus TCP/RTU Protocol for SCADA Integration
  • Support XW-Board I/O Expansion Board
  • Support I-7000 Remote I/O Modules (Up to 16)
  • Support Modbus RTU Slave Devices (Up to 10)
  • SNTP Time Synchronization Supported
WISE-5800-MTCP

Intelligent I/O Controller with Modbus/TCP Support

  • Built-in IF-THEN-ELSE rule engine for logic operation
  • No more programming. Click and get done!
  • Support I/O, Counter, Timer, Email, Recipe operations
  • Data logger and data files send back function supported
  • Modbus TCP/RTU Protocol for SCADA Integration
  • Support XW-Board I/O Expansion Board
  • Support Modbus TCP Slave Devices (Up to 7)
  • SNTP Time Synchronization Supported
WISE-5801

Intelligent I/O Controller with Modbus/RTU and SMS Support

  • Built-in IF-THEN-ELSE rule engine for logic operation
  • No more programming. Click and get done!
  • Support I/O, Counter, Timer, Email, Recipe operations
  • Data logger and data files send back function supported
  • Modbus TCP/RTU Protocol for SCADA Integration
  • Support XW-Board I/O Expansion Board
  • Support I-7000 Remote I/O Modules (Up to 16)
  • Support Modbus RTU Slave Devices (Up to 10)
  • SNTP Time Synchronization Supported
  • Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)
WISE-5801-MTCP

Intelligent I/O Controller with Modbus/TCP and SMS Support

  • Built-in IF-THEN-ELSE rule engine for logic operation
  • No more programming. Click and get done!
  • Support I/O, Counter, Timer, Email, Recipe operations
  • Data logger and data files send back function supported
  • Modbus TCP/RTU Protocol for SCADA Integration
  • Support XW-Board I/O Expansion Board
  • Support Modbus TCP Slave Devices (Up to 7)
  • SNTP Time Synchronization Supported
  • Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)

WISE-580x I/O Module Support Specification

I/O Module Support WISE-580x WISE-580x-MTCP
Local Expansion for XW-board
(supports one XW-board only)
YES YES
Remote I/O Interface by RS485 I-7000 modules (up to 16) or
Modbus/RTU modules (up to 10)
NO
Remote I/O Interface by Ethernet NO Modbus/TCP Slave modules (up to 7)

WISE-580x Support List

I/O Type I/O Function Supported Modules
Local Expansion
XW-board
DI / DO XW107, XW110
DI / DO / AI / AO XW304, XW310, XW310C
I-7000 Module AI / AO Voltage & Current I-7012, I-7012D, I-7012F, I-7012FD, I-7017, I-7017F, I-7017R, I-7017C, I-7017FC, I-7017RC, I-7017R-A5, I-7017Z
Thermocouple I-7011, I-7011D, I-7011P, I-7011PD, I-7018, I-7018P, I-7018R, I-7018Z, I-7019R
RTD I-7013, I-7013D, I-7015, I-7015P, I-7033, I-7033D
Thermistor I-7005
Transmitter I-7014D
Strain Gauge I-7016, I-7016D, I-7016P, I-7016PD
Analog Output I-7021, I-7021P, I-7022, I-7024, I-7024R
DI / DO DC Digital Input I-7041, I-7041D, I-7041P, I-7041PD, I-7051, I-7051D, I-7052, I-7052D, I-7053-FG, I-7053D-FG
AC Digital Input I-7058, I-7058D, I-7059, I-7059D
DC Digital Output I-7042, I-7042D, I-7043, I-7043D, I-7045, I-7045D, I-7045-NPN, I-7045D-NPN
DC Digital Input & Output I-7044, I-7044D, I-7050, I-7050D, I-7050A, I-7050AD, I-7055, I-7055D, I-7055-NPN, I-7055D-NPN
Relay Output Power Relay Output I-7060, I-7060D, I-7061, I-7061D, I-7063, I-7063D, I-7065, I-7065D, I-7067, I-7067D
Solid State Relay Output I-7063A, I-7063AD, I-7063B, I-7063BD, I-7065A, I-7065AD, I-7065B, I-7065BD
Photomos Relay Output I-7066, I-7066D
Others Counter / Frequency I-7080, I-7080D, I-7080B, I-7080BD, I-7088
M-7000 Module or Modbus/RTU Slave Coil Output / Discrete Input / Input Register / Holding Register

WISE-580x-MTCP Support List

I/O Type I/O Function Supported Modules
Local Expansion
XW-board
DI / DO XW107, XW110
DI / DO / AI / AO XW304, XW310, XW310C
Modbus/TCP Slave Module Coil Output / Discrete Input / Input Register / Holding Register
XW107

8-channel Non-Isolated Digital Input
8-channel Non-Isolated Digital Output

  • Digital Input
    • Channels: 8
    • Type: Dry (Source)
    • On Voltage Level: Close to GND
    • Off Voltage Level: Open
  • Digital Output
    • Channels: 8
    • Type: Open collector (Sink)
    • Load Voltage: 10~30Vdc
    • Max Load Current: 100mA/Channel
XW107i

8-channel Isolated Digital Input
8-channel Isolated Digital Output

  • Digital Input
    • Channels: 8
    • Type: Wet (Sink/Source)
    • On Voltage Level: 10~50Vdc
    • Off Voltage Level: 4Vdc Max
  • Digital Output
    • Channels: 8
    • Type: Open collector (Sink)
    • Load Voltage: 10~40Vdc
    • Max Load Current: 200mA/Channel
XW110i

16-channel Isolated Digital Input

  • Digital Input
    • Channels: 16
    • Type: Wet, Dry (Sink/Source)
    • On Voltage Level:
      • Wet Contact: 10~50Vdc
      • Dry Contact: Close to GND
    • Off Voltage Level:
      • Wet Contact: 4Vdc Max
      • Dry Contact: Open
XW111i

16-channel Isolated Digital Output

  • Digital Input
    • Channels: 16
    • Type: Open Collector (Sink)
    • Load Voltage: 10~50Vdc
    • Max Load Current: 350mA/Channel
XW304

6-channel Voltage Input
1-channel Voltage Output
4-channel Digital Input
4-channel Digital Output

  • Analog Input
    • Channels: 6
    • Range: ±5V, 0~5V
    • Resolution: 12-bit
    • Sampling Rate: 4kHz
  • Analog Output
    • Channels: 1
    • Range: ±5V
    • Resolution: 12-bit
    • Capacity: 20mA
  • Digital Input
    • Channels: 4
    • Type: Dry
    • On Voltage Level: Close to GND
    • Off Voltage Level: Open
  • Digital Output
    • Channels: 4
    • Type: Open collector (Sink)
    • Load Voltage: 10~40Vdc
    • Max Load Current: 200mA/Channel
XW310

4-channel Voltage Input
2-channel Voltage Output
3-channel Digital Input
3-channel Digital Output

  • Analog Input
    • Channels: 4
    • Range: ±10V
    • Resolution: 12-bit
    • Sampling Rate: 4kHz
  • Analog Output
    • Channels: 2
    • Range: ±10V
    • Resolution: 12-bit
    • Capacity: 20mA
  • Digital Input
    • Channels: 3
    • Type: Dry
    • On Voltage Level: Close to GND
    • Off Voltage Level: Open
  • Digital Output
    • Channels: 3
    • Type: Open collector (Sink)
    • Load Voltage: 10~40Vdc
    • Max Load Current: 200mA/Channel
XW310C

4/8-channel Current Input
2-channel Current Output
3-channel Digital Input
3-channel Digital Output

  • Analog Input
    • Channels: 4 (Differential) / 8 (Single-ended)
    • Range: 0~20mA
    • Resolution: 12-bit
    • Sampling Rate: 4kHz
  • Analog Output
    • Channels: 2
    • Range: 0~20mA
    • Resolution: 12-bit
    • Capacity: 20mA
  • Digital Input
    • Channels: 3
    • Type: Dry
    • On Voltage Level: Close to GND
    • Off Voltage Level: Open
  • Digital Output
    • Channels: 3
    • Type: Open collector (Sink)
    • Load Voltage: 10~40Vdc
    • Max Load Current: 200mA/Channel
XW506

6-port Non-Isolated RS-232

  • COM Ports
    • Ports: 6 x RS-232
    • Baud Rate: up to 115,200 bps
    • Parity: None, Even, Odd, Mark, Space
    • Data Bits: 5, 6, 7, 8
    • Stop Bits: 1, 1.5, 2
    • FIFO Size: 16 bytes/port
XW507

1-port Non-Isolated RS-422/485
5-channel Isolated Digital Input
5-channel Isolated Digital Output

  • Digital Input
    • Channels: 5
    • Type: Wet (Sink/Source)
    • On Voltage Level: 10~50Vdc
    • Off Voltage Level: 4Vdc Max
  • Digital Output
    • Channels: 5
    • Type: Open collector (Sink)
    • Load Voltage: 10~40Vdc
    • Max Load Current: 200mA/Channel
  • COM Ports
    • Ports: 1 x RS-422/485
    • Baud Rate: up to 115,200 bps
    • Parity: None, Even, Odd, Mark, Space
    • Data Bits: 5, 6, 7, 8
    • Stop Bits: 1, 1.5, 2
    • FIFO Size: 128 bytes
XW509

2-port Non-Isolated RS-232
4-channel Isolated Digital Input
4-channel Isolated Digital Output

  • Digital Input
    • Channels: 4
    • Type: Wet (Sink/Source)
    • On Voltage Level: 10~50Vdc
    • Off Voltage Level: 4Vdc Max
  • Digital Output
    • Channels: 4
    • Type: Open collector (Sink)
    • Load Voltage: 10~40Vdc
    • Max Load Current: 200mA/Channel
  • COM Ports
    • Ports: 2 x RS-232
    • Baud Rate: up to 115,200 bps
    • Parity: None, Even, Odd, Mark, Space
    • Data Bits: 5, 6, 7, 8
    • Stop Bits: 1, 1.5, 2
    • FIFO Size: 16 bytes
XW511i

4-port Isolated RS-485

  • COM Ports
    • Ports: 4 x RS-485
    • Baud Rate: up to 115,200 bps
    • Parity: None, Even, Odd, Mark, Space
    • Data Bits: 5, 6, 7, 8
    • Stop Bits: 1, 1.5, 2
    • FIFO Size: 128 bytes
XW514

8-port Non-Isolated RS-485

  • COM Ports
    • Ports: 8 x RS-485
    • Baud Rate: up to 115,200 bps
    • Parity: None, Even, Odd, Mark, Space
    • Data Bits: 5, 6, 7, 8
    • Stop Bits: 1, 1.5, 2
    • FIFO Size: 128 bytes

WISE-5800
WISE-5801
WISE-5800-MTCP
WISE-5801-MTCP
XW107
XW107i
XW110i
XW111i
XW304
XW310
XW310C
XW506
XW507
XW509
XW511i
XW514